2706-TB Tank System (CUG-40)
[TSD ID#: TS-2-7]
The 2706-TB Tank System is housed in the 2706-TB Building, which is adjacent to the 2706-T and 2706-TA buildings (on the north side).
These three buildings are commonly referred to as the 2706-T Facility. The 2706-T Facility is located west of the 221-T Canyon Building.
The primary purpose of the 2706-TB Building is to enclose and protect the tank system.
The 2706-TB Building was constructed in 1998. The building measures 37.5 ft wide, 25.3 ft long, and 31 ft high.
The building foundation is a coated curbed concrete floor that forms a containment basin approximately 2 ft below grade.
This basin surface is covered with a high-density epoxy coating free of cracks and gaps, which slopes to a coated sump.
An open metal grating forms an elevated working platform about 3.5 ft above the containment basin floor.
The 2706-TB Building primary and secondary structural elements are made of prefabricated steel.
Enforceable Permit:
Issued in accordance with the applicable provisions of the Hazardous Waste Management Act, Chapter 70A.300 Revised Code of Washington (RCW), and the regulations promulgated there under in Chapter 173-303 Washington Administrative Code (WAC).
Permit Number: WA7890008967
Addenda:
- A: Reserved
- B: Reserved
- C: Reserved
- D: Reserved
- E: Reserved
- F: Reserved
- G: Reserved
- H: Closure Plan
- I: Reserved
- J: Reserved